PROMUS™ Element™ Everolimus-Eluting Coronary Stent System

Powered by Platinum Chromium.
HEALTH CARE PROFESSIONALS
Overview

Strength. Flexibility. Visibility.

Experience the next generation in coronary stenting with the PROMUS™ Element™ Everolimus-Eluting Coronary Stent System. Powered by Platinum Chromium and the Element™ Stent design, the PROMUS™ Element™ Stent is the strongest, most flexible and most visible thin-strut coronary stent.¹

The Strongest Thin-Strut Stent ²
The new design of the PROMUS™ Element™ Stent unlocks the potential of Platinum Chromium. The result is the strongest stent on a 0.0032” (0.081 mm) stent platform.

  • Up to 80% stronger than Endeavor™ and XIENCE V™ Stents
  • Up to 30% less recoil than Endeavor™ and XIENCE V™ Stents


PROMUS Element Strength Image

The Most Visible Thin-Strut Stent ³
Platinum is two times more dense than Cobalt or Iron, giving the Platinum Chromium PROMUS™ Element™ Stent superior radiopacity on a thin-strut stent platform.

The Most Flexible Thin-Strut Stent ¹
The shorter segments, helical two-connector design and nested peaks of the PROMUS™ Element™ Stent enhance deliverability of the stent and stent conformability to the vessel.

PROMUS Element Flexibility Image

PROMUS Element Schematic Image 1

A Highly Deliverable Thin-Strut Drug-Eluting Stent System4

The new Bi-Segment™ inner lumen catheter design and DynaLEAP™ balloon material of the PROMUS™ Element™ Stent System improve both trackability and pushability.

PROMUS Element Flexibility Curve

The Proven Power of Everolimus 5

The PROMUS™ Element™ Stent uses the same anti-proliferative everolimus drug and polymer that have been well established in clinical practice and clinical research with the PROMUS™ Stent.

  • More than 5,000 patients studied in the SPIRIT Clinical Trial Program5, supporting the safety and efficacy of the PROMUS™ Stent
  • More than 1 million everolimus-eluting stents implanted worldwide to date
  • Powerful neointimal suppression
  • Low late loss


Expanded Size Matrix Includes The PROMUS™ Element™ Long 38mm Stent

  Length (mm)
0 (mm) 8 12 16 20 24 28 32 38
2.25 H7493911308220 H7493911312220 H7493911316220 H7493911320220 H7493911324220 H7493911328220 H7493911332220  
2.50 H7493911308250 H7493911312250 H7493911316250 H7493911320250 H7493911324250 H7493911328250 H7493911332250 H7493911338250
2.75 H7493911308270 H7493911312270 H7493911316270 H7493911320270 H7493911324270 H7493911328270 H7493911332270 H7493911338270
3.00 H7493911308300 H7493911312300 H7493911316300 H7493911320300 H7493911324300 H7493911328300 H7493911332300 H7493911338300
3.50 H7493911308350 H7493911312350 H7493911316350 H7493911320350 H7493911324350 H7493911328350 H7493911332350 H7493911338350
4.00 H7493911308400 H7493911312400 H7493911316400 H7493911320400 H7493911324400 H7493911328400 H7493911332400 H7493911338400


Additional Information

1 To Date. Test conducted at Boston Scientific. Data on file. Platinum Chromium Technical Bulletin PDM 90353760.
2 Data on File. Compared to XIENCE V™ and Endeavor™ Stents. Bench tested. Tested performed on TAXUS™ Element™ Stent. Indicative of performance of PROMUS™ Element ™. TAXUS™ Element™ =15, XIENCE V™= 10, Endeavor™ = 3. XIENCE is a trademark of Abbott Laboratories group of companies. Endeavor is a trademark of Medtronic Corporation. Bench test results may not be indicative of clinical performance. TAXUS™ Element™ Paclitaxel-Eluting Coronary Stent System is not available for sale in the United States and Japan.
3 Testing conducted by Boston Scientific. Data on File. Platinum Chromium Technical Bulletin PDM 90353760.
4 Bench testing conducted by Boston Scientific. Data on File. PROMUS™ Element™+ Deliverability Bench Testing Aug2009. PROMUS™ Element™ = 5, TAXUS™ Element™ = 4, XIENCE V™ = 5, TAXUS™ Liberté™ = 5, XIENCE PRIME™ = 4, Cypher™ Select = 5, Endeavor™ Resolute™ = 5.
5 The SPIRIT Clinical program. SPIRIT is sponsored by Abbott Laboratories group of companies.



This material is not intended for use in the United States and Japan. Stent illustrations not indicative of clinical performance. All cited trademarks are the property of their respective owners. CAUTION: The law restricts these devices to sale by or on the order of a physician.

Indications, contraindications, warnings and instructions for use can be found in the product labeling supplied with each device. Information for the use only in countries with applicable health authority product registrations.

Image Gallery
Promus™ Element™ Everolimus-Eluting Coronary Stent System

Product Type

Stent

Used in Procedures

Coronary Angioplasty (PTCA)

Related Medical Areas

Interventional Cardiology

Related Conditions

Heart Conditions